Oskar Hagelskjær
20 nov. 2026
With four times the sample capacity, the new CDS Pyroprobe 6400 gives labs more room for filter samples containing trace amounts of microplastics. Our EasyPyCal™ standard lets labs calibrate for all 12 ASTM D8401-24 polymers using real microplastic fragments in a single mixture.
Our partner CDS Analytical has tested our EasyPyCal™ ASTM D8401-24 calibration standard on its new 6400 Pyroprobe autosampler. CDS reports R² ≥ 0.99 for all 12 polymer target ions. The results build on an earlier CDS study with the Pyroprobe 6150, where all 12 calibration curves achieved R² of 0.99.

What does the larger sample tube offer?
The 6400 has a 50 µL sample capacity, approximately four times that of the 6150 and 6200. For labs analyzing microplastics collected on glass fiber filters, that extra space has a practical benefit. When just a few micrograms of polymer are spread across a filter, a larger tube can accommodate more of the filter in a single run.
One standard, 12 calibration curves (R² ≥ 0.99)
We developed EasyPyCal™ so analysts can weigh out all 12 polymers in a single step. The standard contains cryomilled microplastic fragments dispersed in calcium carbonate at the concentrations specified in ASTM D8401-24 standard methodology. This lets analysts dispense microgram quantities of polymer by weighing milligram quantities of powder, without having to prepare separate polymer solutions.

Calibrating with as little as 0.4 mg of EasyPyCal™
For the 6400 study, CDS weighed 0.4–4 mg of EasyPyCal™ per tube across five calibration levels, each analyzed in triplicate. Even the smallest portion contained only 0.4 mg of powder, making an even distribution of microplastic fragments especially important. Across this tenfold range, CDS measured polymer quantities at the microgram scale and reported R² ≥ 0.99 for all 12 polymer target ions.
The attached application notes include the target ions, chromatograms, and calibration curves for both the new Pyroprobe 6400 and the earlier 6150. Read the full application note.
What’s in the EasyPyCal™ ASTM D8401-24 kit?
Our EasyPyCal™ standard combines real microplastic fragments from all 12 target polymers in a single calcium carbonate blend. The table gives the nominal mass of each polymer in 1 mg of standard, so analysts can calculate the polymer mass in each pyrolysis tube directly from the amount of powder they weigh.
Polymer | Concentration (µg/mg) |
Polyethylene (PE) | 40.0 |
Polypropylene (PP) | 10.0 |
Polyvinyl chloride (PVC) | 10.0 |
Polyamide 6,6 (PA66) | 4.5 |
Polyethylene terephthalate (PET) | 4.0 |
Styrene-butadiene rubber (SBR) | 4.0 |
Acrylonitrile butadiene styrene (ABS) | 4.0 |
MDI-based polyurethane (PU) | 2.5 |
Polystyrene (PS) | 2.0 |
Polymethyl methacrylate (PMMA) | 2.0 |
Polyamide 6 (PA6) | 1.25 |
Polycarbonate (PC) | 1.0 |
View the EasyPyCal™: ASTM D8401-24 kit